CONFORMITY TESTING LABS PVT. LTD.
GST : 07AAFCC1048J1ZS

call images

Call us

07971459757

Testing Glow Wire
Testing Glow Wire

Testing Glow Wire

MOQ : 1 Unit

Testing Glow Wire Specification

  • Interface
  • Digital Control Panel with Timer
  • Measuring Range
  • Ambient to 1000C
  • Display
  • Digital Display
  • Voltage
  • 220 V AC
  • Size
  • Customized / Standard, test pin 4 mm & 5 mm available
  • Power
  • 500 W
  • Driven Type
  • Electrical Motorized and Manual
  • Material
  • Stainless Steel, Heat Resistant Alloys
  • Frequency
  • 50 Hz
  • Usage & Applications
  • Used for testing glow wire ignition, flammability tests on electrical and electronic products
  • Weight
  • Approx. 18 kg
  • Temperature
  • ambient to 1000C (1C control accuracy)
  • Ambient Humidity Range
  • 85%RH
  • Test Duration Timer
  • 1s to 9999s programmable
  • Dimensions (LxWxH)
  • 550 x 380 x 480 mm
  • Specimen Holder Movement
  • Automatic and Adjustable
  • Cooling Fan
  • Built-in exhaust fan for smoke removal
  • Safety Interlock
  • Over-temperature protection, power cut-off safety
  • Test Chamber Material
  • Stainless steel enclosed with glass observation window
  • Glow Wire Diameter
  • 4 mm and 5 mm interchangeable
 

Testing Glow Wire Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Week
  • Delivery Time
  • 7 Days
 

About Testing Glow Wire



Experience the impeccable performance of our featured Glow Wire Testing Chamber, in demand among professionals for its immaculate results. Crafted from premium stainless steel and decorated with a glass observation window, this apparatus is a virtuoso among testing instruments. Benefit from automatic, adjustable specimen holder movement and a programmable timer (1s to 9999s). The test chamber incorporates over-temperature protection, power cut-off safety, and a built-in exhaust fan to maintain safety and visibility. Purchase this state-of-the-art instrument for reliable flammability and ignition testing of electrical and electronic goods. Designed for easy operation through a digital control panel, it ensures consistent results for manufacturers and laboratories. Standard and customized sizes available.

Specific Usage and Expertise in Glow Wire Testing

Testing Glow Wire Chambers are primarily used for flammability and glow wire ignition tests on electrical and electronic components. Utilized as a safety assessment tool, it is indispensable for manufacturers, quality control experts, and product developers. Laboratories and research institutions rely on this equipment to ensure compliance with international safety standards. Its versatile configuration-with automatic and manual operation-makes it suitable for professionals who demand precise and detailed analysis during testing procedures.


Premium Packaging, Sample Policy, and Delivery Service Details

Each Glow Wire Tester is packaged with premium-grade materials to ensure immaculate condition upon receipt. Sample policies are tailored to client requirements-contact us for an estimated policy suited to your project. Delivery time is efficiently managed, with most orders dispatched within the estimated lead time using reputable transport services across India. Our dedicated support ensures that your purchase process is seamless, from order placement to secure arrival at your facility.


FAQ's of Testing Glow Wire:


Q: How does the automatic specimen holder function in the Glow Wire Test Chamber?

A: The automatic and adjustable specimen holder streamlines the testing process by securely positioning the test samples and allowing precise movement, which enhances consistency and repeatability during glow wire ignition and flammability tests.

Q: What safety features are integrated into this Glow Wire Test Chamber?

A: Safety is prioritized with over-temperature protection, automatic power cut-off in case of anomalies, and a built-in exhaust fan for efficient smoke removal, ensuring a secure testing environment for all users.

Q: When should the interchangeable 4 mm and 5 mm test pins be used?

A: The 4 mm and 5 mm test pins are used depending on the specific test standards and specimen requirements. The chamber allows easy swapping to comply with various international flammability test protocols for electrical and electronic products.

Q: Where can this chamber be installed or used effectively?

A: This Glow Wire Test Chamber can be installed in manufacturing facilities, electrical safety laboratories, research institutions, and quality control departments where compliance and safety verification are routinely conducted.

Q: What is the benefit of the digital control panel with timer and temperature settings?

A: The digital control panel enables precise programming of test duration (1s to 9999s) and temperature (ambient to 1000C), offering unmatched control, accuracy, and ease of use for both novice and expert operators.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MAJOR TEST FACILITIES (ENVIRONMENTAL) Category

Testing Tracking

Testing Tracking

Minimum Order Quantity : 1 Unit

Size : Standard as per requirement

Power : 5 Watt (w)

Usage & Applications : Testing Equipment

Frequency : 50 Hertz (Hz)

Interface : Digital

Testing Hot Sir

Testing Hot Sir

Minimum Order Quantity : 1 Unit

Size : Standard

Power : 600 W

Usage & Applications : For Laboratory, Industrial Use

Frequency : 50 Hz

Interface : Digital

Testing ECG Analyzer

Testing ECG Analyzer

Minimum Order Quantity : 1 Unit

Size : 200 mm x 150 mm x 70 mm

Power : 10 W

Usage & Applications : Testing and Calibration of ECG Machines

Frequency : 50 Hz

Interface : RS232, USB

Testing Hot and Cold Chamber

Testing Hot and Cold Chamber

Minimum Order Quantity : 1 Unit

Size : 600 x 600 x 600 mm (Customizable)

Power : 2.5 kW

Usage & Applications : Testing performance of products under varying temperature conditions

Frequency : 50 Hz

Interface : Digital control panel with programmable functions



Back to top