Testing ECG Analyzer Specification

  • Frequency
  • 50 Hz
  • Temperature
  • 0C to 50C
  • Measuring Range
  • 0.05 mV to 2 mV
  • Material
  • ABS Plastic
  • Weight
  • 1.2 kg
  • Power
  • 10 W
  • Voltage
  • 230 V AC
  • Size
  • 200 mm x 150 mm x 70 mm
  • Usage & Applications
  • Testing and Calibration of ECG Machines
  • Interface
  • RS232, USB
  • Display
  • LCD Display
  • Driven Type
  • Electric
  • Accessories
  • Carrying Case, Test Leads, User Manual
  • ECG Waveforms
  • 12 standard leads simulated
  • Test Modes
  • Normal Sinus Rhythm, Arrhythmia
  • Safety
  • IEC 601-1 compliant
  • Indicators
  • LED Status Indicators
  • Battery Backup
  • Rechargeable, up to 6 hours
  • Output Impedance
  • 500 Ohms
 

Testing ECG Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Week
  • Delivery Time
  • 7 Days
 

About Testing ECG Analyzer



Introducing the Testing ECG Analyzer, an in-demand solution engineered for advanced testing and calibration of ECG machines. Featuring 12 simulated standard leads and grandiose array of test modes, it complies with IEC 601-1 safety standards. Boasting astounding battery backup (up to 6 hours) and robust RS232/USB interfaces, it promises unmatched utility. High-quality ABS plastic construction ensures rarefied durability. Ending soon at the best price, it includes comprehensive accessories, LED status indicators, and an intuitive LCD display-making it the ultimate choice for service providers across India.

Versatile ECG Analyzer Applications

The Testing ECG Analyzer serves as an invaluable tool in hospitals, clinics, laboratories, and medical device manufacturing units. Designed for application on medical equipment surfaces, it ensures precise ECG machine calibration and testing. Suitable for both general and specific clinical uses, its seamless function supports equipment verification, performance checks, and routine maintenance, helping healthcare professionals uphold accuracy and reliability standards in patient diagnostics and monitoring.


Payment Options and Goods Transport Details

Testing ECG Analyzer purchases support a variety of convenient payment terms including advance charge and net banking. Sample policies are available for evaluation prior to full order commitment. All shipped goods are dispatched through designated FOB ports, ensuring safe and timely goods transport to your facility. Our comprehensive logistics framework ensures your equipment arrives in optimal condition, allowing for seamless integration into your medical service offerings across India.


FAQ's of Testing ECG Analyzer:


Q: How does the Testing ECG Analyzer simulate 12 standard ECG leads?

A: The analyzer generates accurate ECG waveforms, simulating 12 standard leads for comprehensive performance testing and calibration of ECG machines, ensuring reliable functionality evaluation.

Q: What are the main applications of this ECG Analyzer?

A: This device is ideal for testing and calibrating ECG machines in hospitals, clinics, laboratories, and medical equipment manufacturing facilities, providing both specific and general clinical calibration.

Q: When should the battery be recharged for optimal operation?

A: The rechargeable battery lasts up to 6 hours. It is recommended to recharge the device after each extended use or whenever the LED indicator signals low battery to ensure uninterrupted performance.

Q: Where can the analyzer be used considering its operational range?

A: It can be safely operated indoors across temperatures from 0C to 50C, making it versatile for use in diverse hospital, laboratory, and field settings.

Q: What process should be followed for the initial setup?

A: Simply connect the analyzer using the provided test leads, follow user manual guidelines, connect via RS232 or USB if needed, and use the LCD display to configure desired test modes.

Q: How does the device enhance the calibration process for service providers?

A: By offering simulated waveforms, safety compliance, and multi-mode testing, it streamlines accurate calibration, reducing equipment downtime and improving diagnostic reliability in your medical facility.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MAJOR TEST FACILITIES (ENVIRONMENTAL) Category

Testing Hot Sir

Testing Hot Sir

Minimum Order Quantity : 1 Unit

Power : 600 W

Weight : Approx. 45 Kg

Driven Type : Electric

Display : Digital

Interface : Digital

Testing Tracking

Testing Tracking

Minimum Order Quantity : 1 Unit

Power : 5 Watt (w)

Weight : Light Weight

Driven Type : Electric

Display : Digital

Interface : Digital

Vacuum Testing

Vacuum Testing

Minimum Order Quantity : 1 Unit

Power : 500 Watt (w)

Weight : 1050 Kilograms (kg)

Driven Type : Electric

Display : Digital

Interface : Digital

Testing Hot and Cold Chamber

Testing Hot and Cold Chamber

Minimum Order Quantity : 1 Unit

Power : 2.5 kW

Weight : Approx. 190 kg

Driven Type : Electric

Display : LED / LCD digital display

Interface : Digital control panel with programmable functions



Back to top